NIRS™ DS3 for oil processing

NIRS™ DS3 for oil processing

Advanced analysis providing full confidence in your oil crushing process. The innovative NIRS™ DS3 combines unique analytical performance with the latest software and networking services, making reliable test data for decision-making more available than ever. It’s a complete solution that supports all aspects of your analytical operations from calibration development to measurement and data integration.

Value

Value

Save time and money in your evaluation of raw materials and oilseed products. Produce closer to specification and ensure consistent final product by controlling quality throughout your manufacturing process.

Type sample

Type sample

Whole oilseeds, flakes, press cake, oilseed meals and pellets. Tests can be performed on ground and unground materials with no or very limited sample preparation.

Parameters

Parameters

Protein, moisture, fat, fibre, ash, colour and oleic and linoleic acids.

Slides

Automated sample transfer

Automated sample transfer reduces time spent on transferring data to and from management systems

Smart Start

The Smart Start function ensures that your NIRS DS3 is ready to measure without having to wait for diagnostics. Just start the shift and start measuring.

Ready-to-use calibrations or tools to develop your own

FOSS global ANN calibrations are built on thousands of samples from a large variety of raw materials. Alternatively, develop your own calibrations with the easy to use FossCalibrator™ tool.

Versatile performance

Advanced and versatile solution for testing a range of parameters on ground and unground material with no or very limited sample preparation.

Technical specification

Products measured and product presentation
Feature Specification
Dimensions (w x d x h) 375 x 490 x 300 mm
Weight
27 kg
Degree of protection IP 65
Measurement mode Reflectance or transflectance (for liquids)
Wavelength range
400 - 2500 nm
Detector
Silicon (400 - 1100 nm), Lead Sulphide, PbS (1100 - 2500 nm)
Optical bandwidth 8.75 ± 0.1 nm
Data resolution 0.5 nm
Number of data points

4200

Number of subsamples Default: 7 for small cup; 8 for large cup
Self test 12 minutes (variable)
Analysis time

<1 minute for 32 scans (8 subsamples, 4 scans per subsample)

Installation requirements
Voltage supply
100-240 V AC*, frequency 50-60 Hz, Class 1, protective earth
Ambient temperature 5 - 40°C
Storage temperature
-20 to 70°C
Ambient humidity
< 93% RH
Mechanical environment
Stationary during use
EMC environment
Laboratory use, industry requirements
*Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.
Optimize your instrument performance
Digital services

Streamline your operations and improve your profitability with our FOSS IQX™ digital solutions

Service agreement

With a FOSS service agreement you will secure operational uptime, regulatory compliance, and analytical accuracy